FUJI-HITECH Elevator Collection
Project Support +61 478 932 653
Engineered Elevator Solution

Thang máy bệnh viện

Purpose-designed hospital elevators for the safe, efficient movement of patients, stretchers, clinical staff and medical equipment. FUJI-HITECH catalogue configurations are available in 1,350 kg and 1,600 kg capacities, with long cabins, wide automatic entrances and project-specific speeds up to 1.75 m/s.

Designed forSafety & Reliability
Project approachTailored Engineering

Danh mục: Thương hiệu:
Product Information

Designed Around Your Project Requirements

Review the product description and available specifications. Our team can recommend the right configuration for your building and operating needs.

Healthcare Transportation Solutions

Reliable Patient Movement Designed for Clinical Environments

FUJI-HITECH Hospital Elevators are purpose-designed to support the movement
of patients, stretchers, healthcare staff and medical equipment. Long cabins,
wide automatic entrances and project-specific speed selections help deliver
dependable vertical transportation across hospitals and healthcare facilities.

Rated load1,350-1,600 kg
Rated speed1.0-1.75 m/s
Cabin length2,300-2,400 mm
Door opening1,000-1,200 mm

01

Healthcare Performance

Built Around Patient Care and Clinical Workflow

01

Stretcher-Sized Cabin

Long cabin proportions support hospital stretchers, accompanying staff and essential medical equipment.

02

Wide, Clear Entrances

Automatic openings from 1,000 to 1,200 mm help provide practical access for beds, trolleys and wheelchairs.

03

Clinical-Grade Planning

Capacity, speed, shaft and control requirements are coordinated with the healthcare building and operating demands.

02

Configuration Options

Two Capacities for Different Healthcare Requirements

1350

1,350 kg Hospital Elevator

A stretcher-elevator configuration with a long 1,300 x 2,300 mm cabin and two-panel centre-opening entrance.

  • Rated speeds: 1.0, 1.5 or 1.75 m/s
  • 2CO automatic door arrangement
  • Door widths: 1,000 or 1,100 mm
  • Machine-room height: minimum 2,200 mm
1600

1,600 kg Hospital Elevator

A higher-capacity configuration with a 1,400 x 2,400 mm cabin for larger clinical transport requirements.

  • Rated speeds: 1.0, 1.5 or 1.75 m/s
  • 2SO automatic door arrangement
  • Door widths: 1,100 or 1,200 mm
  • Machine-room height: minimum 2,500 mm
03

Technical Overview

Hospital Elevator Catalogue Specifications

Load / configuration Speed Door Shaft size Cabin size Minimum pit / overhead
1,350 kg – 1,000 mm opening 1.0 / 1.5 / 1.75 m/s 2CO, 1,000 x 2,100 mm 2,200 x 2,750 mm 1,300 x 2,300 mm 1,400 / 4,200; 1,500 / 4,300; 1,600 / 4,400 mm
1,350 kg – 1,100 mm opening 1.0 / 1.5 / 1.75 m/s 2CO, 1,100 x 2,100 mm 2,400 x 2,750 mm 1,300 x 2,300 mm 1,400 / 4,200; 1,500 / 4,300; 1,600 / 4,400 mm
1,600 kg – 1,100 mm opening 1.0 / 1.5 / 1.75 m/s 2SO, 1,100 x 2,100 mm 2,300 x 2,900 mm 1,400 x 2,400 mm 1,500 / 4,500; 1,600 / 4,600; 2,700* / 4,700 mm
1,600 kg – 1,200 mm opening 1.0 / 1.5 / 1.75 m/s 2SO, 1,200 x 2,100 mm 2,400 x 2,900 mm 1,400 x 2,400 mm 1,500 / 4,500; 1,600 / 4,600; 1,700 / 4,700 mm

Engineering note: Dimensions are catalogue reference values
in millimetres and are listed in speed order: 1.0, 1.5 and 1.75 m/s.
*The catalogue shows a 2,700 mm minimum pit for the 1,600 kg, 1,100 mm-door,
1.75 m/s row; this value must be verified during project engineering. If a
required size is not listed, the catalogue states that it may be designed
according to the building size. Final requirements must comply with the
selected equipment and applicable project standards.

04

Operation & Safety

Functions Supporting Dependable Healthcare Service

Selective Collective Control

Organises calls by travel direction and sequence to support efficient daily service.

Door Safety Interlock

Prevents travel unless the cabin and landing entrances are correctly secured.

Light-Ray Door Protection

Reopens automatic doors when an obstruction is detected during closing.

Overload Holding Stop

Provides a warning and prevents movement until excessive load is removed.

Emergency Lighting

Maintains cabin illumination when the normal electrical supply is interrupted.

Automatic Power-Failure Rescue*

Selected configurations can use backup power to support safe passenger release.

Emergency Communication

Supports communication from the cabin when clinical staff or passengers require assistance.

Fire Emergency Operation*

Can return the elevator to a predetermined evacuation floor when the option is specified.

*Availability depends on the selected controls and project specification.

05

Cabin Design

Durable Details for Clinical Environments

Cabin wallsDurable stainless-steel or project-selected healthcare finishes
ProtectionWall protection and handrails coordinated with clinical use
LightingBright, efficient LED illumination for clear visibility
FlooringDurable, easy-care project-selected flooring
FixturesClearly arranged cabin and landing operating controls
EntranceWide 2CO or 2SO automatic doors by capacity

Suitable Applications

Healthcare Transportation Planned Around the Facility

  • Public and private hospitals
  • Medical and surgical centres
  • Specialist clinics
  • Rehabilitation facilities
  • Aged-care and assisted-living facilities
  • Healthcare modernisation projects

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “Hospital Elevators”

01

Project Consultation

Professional advice tailored to the building, application and expected traffic.

02

Kỹ thuật chất lượng

Careful system selection and workmanship support safe, dependable performance.

03

Long-Term Support

Responsive assistance from consultation and installation through ongoing service.

Need Technical Advice?

Let’s Specify the Right Elevator for Your Project.

Send us your building requirements and our team will recommend a suitable elevator configuration and project solution.